配置阵列热迁移
megacli -ldrecon -start -r1 -add -physdrv[32:25] -l0 -a0
其中:
32是enclosure的编号,25是physical disk的编号,使用megacli -pdlist -a0可以查看
l0是logic disk的编号,使用megacli -ldinfo -Lall -a0可以查看
查看迁移状态
~# megacli -LDInfo -L0 -a0
Adapter 0 -- Virtual Drive Information:
Virtual Drive: 0 (Target Id: 0)
Name :
RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0
Size : 278.875 GB
Sector Size : 512
Parity Size : 0
State : Optimal
Strip Size : 64 KB
Number Of Drives : 1
Span Depth : 1
Default Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteThrough, ReadAheadNone, Cached, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy : Disk's Default
Ongoing Progresses:
Reconstruction : Completed 14%, Taken 30 min.
Encryption Type : None
Default Power Savings Policy: Controller Defined
Current Power Savings Policy: None
Can spin up in 1 minute: Yes
LD has drives that support T10 power conditions: Yes
LD's IO profile supports MAX power savings with cached writes: No
Bad Blocks Exist: No
Is VD Cached: No
Exit Code: 0x00