使用MegaCli64设置硬件阵列卡,单盘raid0热迁移为双盘raid1

文章目录[隐藏]

配置阵列热迁移



megacli -ldrecon -start -r1 -add -physdrv[32:25] -l0 -a0

其中:
32是enclosure的编号,25是physical disk的编号,使用megacli -pdlist -a0可以查看
l0是logic disk的编号,使用megacli -ldinfo -Lall -a0可以查看

查看迁移状态



~# megacli -LDInfo -L0 -a0

Adapter 0 – Virtual Drive Information: Virtual Drive: 0 (Target Id: 0) Name : RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0 Size : 278.875 GB Sector Size : 512 Parity Size : 0 State : Optimal Strip Size : 64 KB Number Of Drives : 1 Span Depth : 1 Default Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteThrough, ReadAheadNone, Cached, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy : Disk’s Default Ongoing Progresses: Reconstruction : Completed 14%, Taken 30 min. Encryption Type : None Default Power Savings Policy: Controller Defined Current Power Savings Policy: None Can spin up in 1 minute: Yes LD has drives that support T10 power conditions: Yes LD’s IO profile supports MAX power savings with cached writes: No Bad Blocks Exist: No Is VD Cached: No

Exit Code: 0x00


This article is under CC BY-NC-SA 4.0 license.
Please quote the original link:https://www.liujason.com/article/1188.html
Licensed under CC BY-NC-SA 4.0